Page 70 - PHU_User Manual_EN_Rev A
P. 70

PHU Series User Manual

               750-60      (0.1 to 1500.0) V/S     (0.01 to 120.00) A/S
               1000-45     (0.1 to 2000.0) V/S     (0.01 to 90.00) A/S
               1500-30     (0.1 to 3000.0) V/S     (0.001 to 60.000) A/S


               Panel Lock
               The panel lock feature prevents settings from being changed
               accidentally. When activated, the Lock key will become illuminated
               and all keys and knobs except the Lock key and Output key (if
               active) will be disabled.

               If the instrument is remotely controlled via the USB/LAN interface,
               the panel lock is automatically enabled.

               Activate the panel  Press the Lock key to active the panel   Unlock
               lock           lock. The key will become illuminated.   Lock

               Disable the panel  Hold the Lock key for 3 seconds to   Unlock
               lock           disable the panel lock. The key’s light   Lock
                              will turn off.


               Save (memory) Setup

               The PHU has 3 memory slots (M1, M2, M3) to save the various
               settings. Including Voltage, Current, Power, Resistance, OVP, OVP
               Delay, OCP, OCP Delay, OPP, OPP Delay, UVL, OVL, UCL, OCL,
               OPL, ORL, Bleeder Control and so on.

               Steps           1.  Press the Menu button to enter the   Menu
                                 main menu.                          Hardcopy